en
MVR Evaporator
MVR Evaporator

Mechanical Vapour Recompression

Brand: WTEYA GROUP
MOQ: 1 Pieces
Delivery time: 15 Day
MVR inorganic water evaporator is a equipment using mechanical vapor compression technology (MVR) to evaporate efficiently and clean inorganic sewage.
Mechanical vapor recompression technology, referred to as MVR. It is an efficient energy-saving technology.
Based on the advanced film separation technology, MVR focusing and evaporator, wittya company offers inorganic waste water MVR evaporator and solution to the industry in the direction of energy saving and environmental protection.This technology significantly reduces the need for external energy by recovering and reusing the energy of the secondary steam produced during the evaporation process.
Product Details

Product introduction

 

Introduction to mechanical vapour recompression

 

Mechanical vapour recompression, namely Mechanical Vapor Recompression (MVR) technology. It significantly reduces the need for external energy by recovering and reusing the secondary steam energy generated during the evaporation process.

In mechanical vapour recompression, a mechanical compressor or fan is used to recompress the secondary steam after the evaporation process, thereby increasing its enthalpy value. The enthalpy-increased steam is returned to the heating chamber as a heat source to heat the feed and is eventually converted into condensed water for discharge. After the material is heated, evaporated and concentrated, it is discharged from the system as the final product.

 

 

Steam recompression machinery composition

 

The vapor recompression mechanical system consists of evaporator, separator, compressor, vacuum pump, circulation pump, operating platform, electrical instrument control cabinet, valves, pipelines and other main parts, forming a complete set of high-efficiency and energy-saving solutions.

 

 

Characteristics of mechanical vapour recompression

 

Significant energy saving effect: The steam recompression machinery only needs a small amount of raw steam to operate, significantly reducing operating costs and environmental pollution, and there is no waste heat steam emission.
Improve product quality: Using a compressor for heat supply, compared with traditional evaporators, the temperature difference is smaller and can achieve gentle evaporation, which helps to improve product quality and reduce scaling.
Simple operation and maintenance: The system design is simple, supports fully automatic operation, and can run continuously to ensure safety and reliability.
Easy to clean: The equipment has a built-in CIP cleaning pipeline, which facilitates on-site cleaning. It is easy to operate and has no cleaning dead corners.
Wide range of material adaptability: It is suitable for materials processed by single-effect and multi-effect evaporators. It can completely replace traditional technology and has better environmental protection and energy-saving performance.

 

 

Application fields of mechanical vapour recompression

 

Chemical industry: Used for solution concentration and extraction of pure solvents, effectively reducing energy consumption.
New energy industry: Such as material recycling or purification processes in battery manufacturing.
Food industry: Concentrate juice, syrup and other liquids to increase concentration and retain flavor.
Coal chemical industry: Effective treatment and recycling of wastewater containing chemical substances.
Electric power industry: Such as power plant desulfurization wastewater treatment, reducing costs and improving water resource recycling rate.
Electroplating industry: Purify and recycle wastewater containing heavy metals and other harmful substances.
Environmental protection field: Address environmental issues such as high-salt wastewater treatment and landfill leachate treatment, reduce pollutant emissions, and meet environmental protection standards.

 

 

Technical principle of

 

MVR inorganic water evaporator uses mechanical vapor compression (MVR) technology. This technique compressed the evaporator by compressor, expanding its temperature and pressure, and then applied to the evaporator to evaporate again. By this way, the one side can significantly reduce energy consumption during the evaporator, on the other hand can also improve the evaporative efficiency and reach the efficient inorganic water treatment.

 

 

The production process of

 

xx

 

Production of equipment

 

xx

 

Wteya aims to digital and intelligent production to provide superior products and services to its customers. We not only provide a wide range of standard products which are seriously tested and stable performance to meet a wide range of industrial needs. We also provide custom service, as well as OEM and ODM services, professional design team provides proper solutions for customers to meet their unique needs. We will work closely with each customer to ensure that every device suits customer's process requirements and production process accurately. Wteya's one-stop service, innovative to create high-quality mechanical products and system solutions, professionally help customer deal with various water treatment problems.

 

 

Capacity and size

 

MVR system parameter board

Evaporator (T/h)

Evaporative way to make

Total energy (kW/h)

Steam consumption (T/h)

Reuse water consumption (T/h)

Area of the (length, height/m)

0.5

MVR, loop required

70

0-0.03

10

6*3*5

1

MVR, loop required

110

0-0.05

10

9*8*6

1.5

MVR, loop required

180

0-0.05

20

12*7.5*9

2

MVR, loop required

213.5

0-0.1

30

12*8*10

3

MVR, loop required

275

0-0.1

50

15*8*15

5

MVR, loop required

425

0-0.2

50

15*10*15

7.5

MVR, loop required

580

0-0.3

70

15*12*15

10

MVR, loop required

815

0-0.3

100

12*6*18

 

Temperature panel parameters

Evaporator (T/h)

Heat exchanger type

Specification (specification)

The material is material

Qty of the quantity

Used to have

0.5

Two horizontal pipe,

Circulation required round

S = 50m ², galls 500 × 6000 × 5mm

TA2

1

 

1

Two horizontal pipe,

Circulation required round

S = 100m ², Nils 650 × 6000 × 5mm

TA2

1

 

1.5

Two horizontal pipe,

Circulation required round

S = 150m ², galls 800 × 6000 × 5mm

TA2

1

 

2

Two horizontal pipe,

Circulation required round

S = 200m ², Nils 800 × 5mm

TA2

1

 

3

Two horizontal pipe,

Circulation required round

S = 260m ², galls 1000 × 6000 × 5mm

TA2

1

 

5

Two horizontal pipe,

Circulation required round

S = 450m ², Nils 1300 × 6000 × 6mm

TA2

1

 

7.5

Two horizontal pipe,

Circulation required round

S = 650m ², Nils 1500 × 6000 × 6mm

TA2

1

 

10

Two horizontal pipe,

Circulation required round

S = 880m ², Nils 1800 × 6000 × 8mm

TA2

1

 

 

 

Chart of effect chart

xx

 

 

Frequently Asked Questions

 

Q: MVR forced evaporator to run?

Cause: could be the corrosion of secondary steam pipes or steam compressors, pure water quality does not meet the standards, or at the point of equipment such as welding, flange, sealing, expansion, and so on.

Solution: ensure water quality into standards, regularly cleaning the system, maintain stable cooling water temperature, and provide a complete amount of cooling water.

 

Q: The steam reduction charged by MVR?
Cause: could be due to system clogging or dirt in the hot water catheter.
Solution: do online purification programs for cleaning dirt.

 

Q: The effect of steam valve charged by MVR?
Cause: The material is processed after thickening, crystally, resulting in clogging.
Solution: The Prevention includes regular filter of salt and spray as well, once stuck, use juice or vacuum treatment.

 

Q: MVR compulsory evaporator effect?
Expression: Produces regular and loud sound, vibrates the pipes.
Solution: constant current stability compressor when counter rate is soft and open the valve through the appropriate rate; counter rate need to close the compressor immediately for testing, pay attention to liquid temperature to avoid counter rate.

 

Q: cool MVR evaporator don't work properly?
Cause: could be due to too thick dust, or vacuum drop.
Solution: add agent foaming agent, check detector and dehumidifying liquid, import steam valve adjustment, vacuum control.

 

 

S/N Single effect evaporator Multi effect evaporator TVR evaporator MVR evaporator
Energy source Using steam heating
Steam pipe network
Need boiler
Using steam heating
Steam pipe network
Need boiler
Need high pressure steam to drive,
Need boiler
Using electric power,
no need steam pipe network
close loop circulation system
Energy consumption 1 tons steam for 1ton water evaporation 0.3~1tons steam for 1ton water evaporation Based on traditional multi effect, one more effect is used with high pressure steam drive The most energy saving technology at present
Operation cost Much higher More energy saving Lower Lowest
Footprint smaller bigger bigger smaller
Product quality Short residence time,
Bigger temp. difference lead to easy scale.
product quality not stable
Longer residence time,
Bigger temp. difference lead to easy scale.
product quality not stable
Short residence time,
Smaller influence on product quality
Short residence time,
Low temp. evaporation,
Minimum impact on product quality
Control type Semi-automatic Full automatic
Uninterrupted evaporation
Full automatic
Uninterrupted evaporation
Full automatic
Uninterrupted evaporation