10t/h MVR evaporator, the choice of high efficiency and energy saving, using mechanical steam recompression technology to recover secondary steam, significantly reducing energy consumption. Suitable for chemical, food, pharmaceutical and other industries, to meet the concentration, crystallization, drying and other process needs. Easy to operate, small footprint, environmentally friendly.
WTEYA provides professional MVR evaporator system, one-stop service, we not only have the production of MVR evaporator system standardized products, but also provide OEM and ODM customized services, we are looking for partners, agents in countries around the world.
Product Details

Product introduction

10t/h MVR evaporator composition
The 10t/h MVR evaporator system consists of the following main components: evaporator, separator, compressor, vacuum pump, circulating pump, operating platform, electrical instrument control cabinet and various necessary valves and pipelines. These components work together to ensure an efficient and stable evaporation process.

10t/h MVR evaporator features
1. High efficiency and energy saving: The system uses mechanical steam recompression technology to significantly reduce energy consumption and improve heat utilization efficiency. Energy consumption is significantly reduced by recycling secondary steam.
2. Compact design: The evaporator covers a small area, compact design, easy installation and maintenance, especially suitable for limited space places.
3. Environmental performance: Reduce the burden on the environment by realizing zero waste water discharge and resource utilization, and meet the current strict environmental protection standards.
4. Automated operation: equipped with advanced intelligent control system, simplifying the operation process, reducing labor costs, and improving the accuracy and reliability of the operation.

10t/h MVR evaporator applications
10t/h MVR evaporators are widely used in many industrial fields due to their efficient performance, especially in industries that require energy-efficient evaporation, crystallization and concentration processes:
1. Chemical industry: concentration of solution or extraction of pure solvent in the chemical production process, MVR evaporator can effectively complete these processes, while greatly reducing energy consumption.
2. Environmental protection: To deal with environmental management problems such as high-salt wastewater and landfill leachate, MVR evaporator provides an effective solution to help reduce pollutant emissions and meet relevant environmental standards.
3. New energy industry: The use of evaporation technology to recover or purify substances in production processes such as battery manufacturing.
4. Food industry: It is used to concentrate juice, syrup and other liquid foods in food processing to improve product concentration while retaining its original flavor.
5. Coal chemical industry: effective treatment and recycling of wastewater containing a variety of chemical substances produced by coal chemical industry.
6. Power industry: It is applied in the treatment of desulfurization wastewater in power plants to reduce treatment costs and improve the recycling rate of water resources.
7. Electroplating industry: used for purification and recovery of wastewater containing heavy metals and other harmful substances produced in electroplating process.

 

Technical principle of

MVR evaporator technical principle for heavy metal sewage:
In the working process of MVR evaporator for heavy metal waste water, the first time sewage is heated to the boiling point by pre-heater. Then it is taken to the body of the evaporator and boiled in it to produce steam, while the heavy metal ions in the sewage water are concentrate. The results steam gets into liquid aerator, separation of pure vapor and concentrated liquid. Pure steam to the return of the evaporator as the heat source after strengthening by the vapor compressor, while the concentrate is further processed or recalled by the exhaust system.

The production process of

xx

Production of equipment

10t/h mvr evaporator

 

Wteya aims to digital and intelligent production to provide superior products and services to its customers. We not only provide a wide range of standard products which are seriously tested and stable performance to meet a wide range of industrial needs. We also provide custom service, as well as OEM and ODM services, professional design team provides proper solutions for customers to meet their unique needs. We will work closely with each customer to ensure that every device suits customer's process requirements and production process accurately. Wteya's one-stop service, innovative to create high-quality mechanical products and system solutions, professionally help customer deal with various water treatment problems.

 

Capacity and size

MVR system parameter board

Evaporator (T/h)

Evaporative way to make

Total energy (kW/h)

Steam consumption (T/h)

Reuse water consumption (t/h)

Area of the (length, height/m)

0.5

MVR, loop required

70

0-0.03

10

6*3*5

1

MVR, loop required

110

0-0.05

10

9*8*6

1.5

MVR, loop required

180

0-0.05

20

12*7.5*9

2

MVR, loop required

213.5

0-0.1

30

12*8*10

3

MVR, loop required

275

0-0.1

50

15*8*15

5

MVR, loop required

425

0-0.2

50

15*10*15

7.5

MVR, loop required

580

0-0.3

70

15*12*15

10

MVR, loop required

815

0-0.3

100

12*6*18

 

Temperature panel parameters

Evaporator (T/h)

Heat exchanger type

Specification (specification)

The material is material

Qty of the quantity

Used to have

0.5

Two horizontal pipe,

Circulation required round

S = 50m ², galls 500 × 6000 × 5mm

TA2

1

 

1

Two horizontal pipe,

Circulation required round

S = 100m ², Nils 650 × 6000 × 5mm

TA2

1

 

1.5

Two horizontal pipe,

Circulation required round

S = 150m ², galls 800 × 6000 × 5mm

TA2

1

 

2

Two horizontal pipe,

Circulation required round

S = 200m ², Nils 800 × 5mm

TA2

1

 

3

Two horizontal pipe,

Circulation required round

S = 260m ², galls 1000 × 6000 × 5mm

TA2

1

 

5

Two horizontal pipe,

Circulation required round

S = 450m ², Nils 1300 × 6000 × 6mm

TA2

1

 

7.5

Two horizontal pipe,

Circulation required round

S = 650m ², Nils 1500 × 6000 × 6mm

TA2

1

 

10

Two horizontal pipe,

Circulation required round

S = 880m ², Nils 1800 × 6000 × 8mm

TA2

1

 

Chart of effect chart

xxxx

 

Frequently Asked Questions

Q: MVR forced evaporator to run?
Cause: could be the corrosion of secondary steam pipes or air compressors, pure water quality does not meet the standards, or at the point of equipment such as welding, flange, sealing, expansion, and so on.
Solution: ensure water quality into standards, regularly cleaning the system, maintain stable cooling water temperature, and provide a complete amount of cooling water.

Problem: MVR is required to deflate slow feeding or a small flow situation?
Reason: usually due to the filter is blocked.
Solution: inspection and purification of filters.

Q: The steam reduction charged by MVR?
Cause: could be due to system clogging or dirt in the hot water catheter.
Solution: do online purification programs for cleaning dirt.

Q: The effect of steam valve charged by MVR?
Cause: The material is processed after thickening, crystally, resulting in clogging.
Solution: The Prevention includes regular filter of salt and spray as well, once stuck, use juice or vacuum treatment.

Q: MVR compulsory evaporator effect?
Expression: Produces regular and loud sound, vibrates the pipes.
Solution: constant current stability compressor when counter rate is soft and open the valve through the appropriate rate; counter rate need to close the compressor immediately for testing, pay attention to liquid temperature to avoid counter rate.

Q: cool MVR evaporator don't work properly?
Cause: could be due to too thick dust, or vacuum drop.
Solution: add agent foaming agent, check detector and dehumidifying liquid, import steam valve adjustment, vacuum control.

Q: MVR is required to circulation irregular level of steam separator?
Cause of the high level: too many data feed, Crystal pump fault or export focus clogging.
Solution: reduce the amount of data input, check the pump, open the drainage pipe.
Cause of the low level: too small or leaking of the concentration tube.
Solution: increase the amount of data input, check the drainage pipe.

S/N Single effect evaporator Multi effect evaporator TVR evaporator MVR evaporator
Energy source Using steam heating
Steam pipe network
Need boiler
Using steam heating
Steam pipe network
Need boiler
Need high pressure steam to drive,
Need boiler
Using electric power,
no need steam pipe network
close loop circulation system
Energy consumption 1 tons steam for 1ton water evaporation 0.3~1tons steam for 1ton water evaporation Based on traditional multi effect, one more effect is used with high pressure steam drive The most energy saving technology at present
Operation cost Much higher More energy saving Lower Lowest
Footprint smaller bigger bigger smaller
Product quality Short residence time,
Bigger temp. difference lead to easy scale.
product quality not stable
Longer residence time,
Bigger temp. difference lead to easy scale.
product quality not stable
Short residence time,
Smaller influence on product quality
Short residence time,
Low temp. evaporation,
Minimum impact on product quality
Control type Semi-automatic Full automatic
Uninterrupted evaporation
Full automatic
Uninterrupted evaporation
Full automatic
Uninterrupted evaporation