Reverse Osmosis Water Treatment Equipment: Pure Efficiency

Brand: WTEYA GROUP
MOQ: 1 Pieces
Delivery time: 15 Day
Reverse osmosis water treatment equipment is an advanced system that uses semi-permeable membrane (RO membrane) technology to effectively remove dissolved substances from water.
When working, the water pressure is raised by a high-pressure pump, forcing it to counterflow through the RO membrane, allowing only water molecules to pass through, thereby trapping contaminants such as salt and bacteria.
The equipment is composed of key components such as pretreatment, membrane separation unit, high pressure pump and post-treatment. The effluent quality is high, and it is widely used in drinking water purification, industrial water, medicine and other fields.
Although wastewater containing concentrated pollutants is produced, its efficient purification capacity and low energy consumption make it an important tool for water resource management.
WTEYA provides professional reverse osmosis membrane water treatment system, one-stop service, we not only have standardized products for the production of reverse osmosis devices, but also provide OEM and ODM customized services, we are looking for partners, agents in countries around the world.
Product Details

Product introduction

 

Free solutions!   Free design!    Guaranteed compliance!
We hope you spend less money on water treatment!
Reverse osmosis water plant has low cost. It is used for seawater desalination, wastewater treatment and industrial pure water.

 

Introduction to reverse osmosis water treatment equipment

Reverse osmosis water treatment equipment uses cutting-edge water purification technology to remove dissolved substances from water through a fine semi-permeable membrane (RO membrane). This includes salts, bacteria, viruses and other impurities. During operation, a high-pressure pump is used to raise the water pressure beyond its natural osmotic pressure, forcing water through the RO membrane. Because the RO membrane's micropores allow only water molecules to pass through, it successfully intercepts most contaminants, a process known as reverse osmosis. Typically composed of key components such as pre-treatment, membrane separation units, high-pressure pumps and post-treatment, the equipment can provide effluent that meets stringent water quality standards and is suitable for use in various fields such as drinking water purification, medicine, laboratory and industrial water. Although some wastewater containing concentrated pollutants is produced during the purification process, its excellent purification effect and relatively low energy consumption make it an important tool for water resource management and protection.

 xx

 

Reverse osmosis water treatment equipment

 

Pretreatment system: Removes suspended matter, chlorine and organic matter through filtration, softening and chemical dosing steps to prevent scaling of RO membranes.
High pressure pump: Increase the water pressure so that the water molecules can flow upstream through the RO membrane.
RO membrane element: As the core of the device, only water molecules are allowed to pass through, while blocking dissolved salts, bacteria and macromolecules.
Flow controller: Adjust the flow rate of produced and concentrated water to optimize the operating efficiency of the system.
Storage and post-treatment system: includes water storage tanks and possible post-treatment devices, such as UV disinfection devices or carbon filters.

 

 

Characteristics of reverse osmosis water treatment equipment

 

Efficient decontamination: Effective removal of a wide range of contaminants such as dissolved salts, particles, bacteria and heat sources.
Excellent effluent quality: The water treated by reverse osmosis water treatment equipment is extremely pure and suitable for a variety of uses, including drinking water and industrial water.
Relatively low energy consumption: Compared to other separation technologies, the device requires less energy during operation.
High degree of automation: Modern equipment enables automatic control, reducing manual intervention and reducing error rates.
Less wastewater generation: Although concentrated water is produced, the amount of wastewater is acceptable compared to its treatment capacity and effectiveness.

 

 

Reverse osmosis water treatment equipment application field

 

Seawater desalination: With excellent desalting capacity, it occupies an important position in the global desalination field, converting seawater into drinkable fresh water.
Industrial pure water preparation: In industrial production processes requiring high purity water quality, such as ultra-pure water preparation in the electronics industry, reverse osmosis water treatment equipment ensures that the water quality meets strict standards.
Wastewater reuse: Suitable for industrial and municipal wastewater treatment, help to reduce environmental pollution, improve the recycling rate of water resources.
Home water purification: ensure the safety and health of family drinking water, remove organic matter, colloids, microorganisms and other particles in the water.

 

In addition, reverse osmosis water treatment equipment is also widely used in agricultural irrigation, food and beverage industry and water quality treatment in the pharmaceutical industry, to ensure that the water quality in all fields meets high standards.

 xx

 

 

Technical principle of

 

RO water treatment system is a method of using semi-automatic membrane technology for the application of water purification based on the principle of osmosis phenomenon and osmosis pressure of yes of solution. In a natural condition, water molecules absorb semi-seepage from low concentration solution to high concentration solution, A process is to reduce the difference of concentration between the two sides until balancing is achieved. Ro is a artificial reverse of this process, which means by applying higher pressure than the external osmosis pressure, tying water molecules from high-concentration solution to low-concentration solution, thereby reaching the purpose of purification.


In RO water treatment system, rough water after pre-treated to eliminate suspension, chlorine and some organic substances, filled with high pressure which is higher than its osmosis pressure. High pressure water is then sent to RO membrane element with micro aperture and select transmission ability, only allows water molecules to pass through and prevent majority of soluble substances such as salt and bacteria. Therefore, when water contact RO membrane, the water molecules enter back through the membrane under the action of pressure to the pure water, while the solubility are trapped at the rough water side, producing two parts of the water flow: One side is pure water (water production) that removes contaminants and the other side is sewage (concentrated water) that contain concentrated pollution.


RO membrane is the core of the whole system and its performance affect directly the separation efficiency and operation efficiency of the system. Film selection must consider the listed ability, water flux, and its anti-pollution to different electrolytes. To maintain ro performance and extend life, the system should be regularly washed in physical or chemical to eliminate accumulated dirt and grow of creatures.

 

 

The production process of

xx

 

Production of equipment

 

xx

 

 

WTEYA aims to digital and intelligent production to provide superior products and services to its customers. We not only provide a wide range of standard products which are seriously tested and stable performance to meet a wide range of industrial needs. We also provide custom service, as well as OEM and ODM services, professional design team provides proper solutions for customers to meet their unique needs. We will work closely with each customer to ensure that every device suits customer's process requirements and production process accurately. WTEYA's one-stop service, innovative to create high-quality mechanical products and system solutions, professionally help customer deal with various water treatment problems.

 

 

 

 

Capacity and size

 

RO Water Treatment Plant parameter chart

Cut out model

Power rating of cloth

Power of installation

Water production quality

Main machine size

The material is made of high quality

WTY-RO2-1

1m³/h

5.5kw

<5 μS/cm

2000 × 1000 × 2000mm(H)

304/

UPVC/

Polyamide/

WTY-RO2-2

2m³/h

6.3kw

<5 μS/cm

2000 × 1000 × 2000mm(H)

WTY-RO2-5

5m³/h

13.2kw

<5 μS/cm

4500 × 2400 × 2400mm(H)

WTY-RO2-10

10m³/h

33.0kw

<5 μS/cm

5000 × 2600 × 2500mm(H)

WTY-RO2-20

20m³/h

67.0kw

<5 μS/cm

6000 × 1800 × 2800mm(H)

8000 × 2600 × 3000mm(H)

 

 

Chart of effect chart

xx

 

Frequently Asked Questions

 

Q: What is the primary purpose of RO Water Treatment Plant System?
Re: the RO Water Treatment Plant System is mainly used to eliminate water-soluble solid substances (such as salt, minerals), bacteria, virus, heavy metal and other impurities, provide high purity of water, suitable for filtration of drinking water, Pharmaceutical production, laboratory water, waste water treatment and other areas.


Q: How about different water quality treatment RO Water Treatment Plant System?
Re: the RO Water Treatment Plant System adapt to different water source scenarios and water quality by adjusting the treatment steps, such as increase the hardness of the softener to eliminate organic substances, use activated carbon filtration to eliminate organic substances, Etc.;


Q: Why does RO Water Treatment Plant System create sewage?
Re: In the RO process, part of water was pressed through the membrane while other part was not, water did not pass by the higher pollution content, this part of water is called dark water or sewage.


Q: How about the filtration rate of RO Water Treatment Plant System?
Re: the salt filtration rate refers to the percentage of salt that is removed in total salt in rough water, which is usually calculated by conductive measurement, as stated in: (1-(water conductivity/water conductivity) × 100%.


Q: How to clean and maintain RO membrane?
Re: RO membrane should be washed regularly to eliminate sedimentation and biological dirt. Cleaning methods include physical cleaning (such as Splash or circulation washing) and chemical cleaning (specific detergents use).


Q: What are the common problems of RO Water Treatment Plant System operation?
Re: Common problems include film pollution, film Damage, system pressure loss, reduce water permeability and lower waste water quality, etc.


Q: How about the energy consumption of RO Water Treatment Plant System?
Re: the energy consumption of the RO Water Treatment Plant System mostly depends on the water pressure and flow that is needed, as well as the pump efficiency in the system. High-pressure pump is the biggest energy consumption, but Ro is generally a relatively energy-saving water treatment technology.


Q: How long life of RO Water Treatment Plant System?
Re: the life of RO Water Treatment Plant System is affected by many factors, such as water quality, operating conditions, maintenance and maintenance. Usually RO membrane may need to be replaced within 3 to 5 years, but the whole system can be designed to last longer and properly maintained which can exceptionally extend service time.