Characteristics of inorganic sewage
Inorganic sewage is mainly from metallurgy, chemicals, electroplate, mining and other industrial production processes. This drain contains a large amount of inorganic salt such as sulfate, nitrate, chloride, etc. V., these substances are not easy to be biodegraded in water and are easily stored, which seriously affect water quality and ecoenvironment. Untreated direct supply can seriously crack the eco balance of the water environment.
Introduction of inorganic sewage MVR evaporator
MVR inorganic water evaporator is a equipment using mechanical vapor compression technology (MVR) to evaporate efficiently and clean inorganic sewage. Through the evaporator process, the sewage water is deflated, allowing inorganic salt to be rich in storage, thus ensuring complete the purification of sewage and recovery of resources. Based on the advanced film separation technology, MVR focusing and evaporator, wittya company offers inorganic waste water MVR evaporator and solution to the industry in the direction of energy saving and environmental protection.
Inorganic water MVR evaporator component
Inorganic water MVR evaporator is mainly including pre-heater, evaporator, separator, compressor, condenser and other parts. Of this, the pre-heater is used to increase the temperature of waste water, the evaporator is used to evaporate the water from waste water, the separator is used to separate evaporator water and remaining inorganic salt, The compressor is used to squeeze the separated steam and the condenser is used to condenser the compressed steam into water.
Advantages of inorganic water MVR evaporator
Inorganic water MVR evaporator with the following advantages:
High efficiency: using MVR technology, high evaporative efficiency and good treatment efficiency.
Energy saving: using extruded thermal energy, reduce energy consumption and reduce operating cost.
Environmentally friendly: Reduces waste of water and reduces environmental pollution.
Safety: equipment is high stable and safe.
Applicable field MVR evaporator inorganic waste water
Inorganic water MVR evaporator is widely used in various industries and sectors such as metallurgy, chemical, electroplate, mining, etc. To create inorganic water. High or low concentration inorganic water can be handled efficiently.
Technical principle of
MVR inorganic water evaporator uses mechanical vapor compression (MVR) technology. This technique compressed the evaporator by compressor, expanding its temperature and pressure, and then applied to the evaporator to evaporate again. By this way, the one side can significantly reduce energy consumption during the evaporator, on the other hand can also improve the evaporative efficiency and reach the efficient inorganic water treatment.
The production process of
Production of equipment
Wteya aims to digital and intelligent production to provide superior products and services to its customers. We not only provide a wide range of standard products which are seriously tested and stable performance to meet a wide range of industrial needs. We also provide custom service, as well as OEM and ODM services, professional design team provides proper solutions for customers to meet their unique needs. We will work closely with each customer to ensure that every device suits customer's process requirements and production process accurately. Wteya's one-stop service, innovative to create high-quality mechanical products and system solutions, professionally help customer deal with various water treatment problems.
Capacity and size
MVR system parameter board |
|||||
Evaporator (T/h) |
Evaporative way to make |
Total energy (kW/h) |
Steam consumption (T/h) |
Reuse water consumption (T/h) |
Area of the (length, height/m) |
0.5 |
MVR, loop required |
70 |
0-0.03 |
10 |
6*3*5 |
1 |
MVR, loop required |
110 |
0-0.05 |
10 |
9*8*6 |
1.5 |
MVR, loop required |
180 |
0-0.05 |
20 |
12*7.5*9 |
2 |
MVR, loop required |
213.5 |
0-0.1 |
30 |
12*8*10 |
3 |
MVR, loop required |
275 |
0-0.1 |
50 |
15*8*15 |
5 |
MVR, loop required |
425 |
0-0.2 |
50 |
15*10*15 |
7.5 |
MVR, loop required |
580 |
0-0.3 |
70 |
15*12*15 |
10 |
MVR, loop required |
815 |
0-0.3 |
100 |
12*6*18 |
Temperature panel parameters |
|||||
Evaporator (T/h) |
Heat exchanger type |
Specification (specification) |
The material is material |
Qty of the quantity |
Used to have |
0.5 |
Two horizontal pipe, Circulation required round |
S = 50m ², galls 500 × 6000 × 5mm |
TA2 |
1 |
|
1 |
Two horizontal pipe, Circulation required round |
S = 100m ², Nils 650 × 6000 × 5mm |
TA2 |
1 |
|
1.5 |
Two horizontal pipe, Circulation required round |
S = 150m ², galls 800 × 6000 × 5mm |
TA2 |
1 |
|
2 |
Two horizontal pipe, Circulation required round |
S = 200m ², Nils 800 × 5mm |
TA2 |
1 |
|
3 |
Two horizontal pipe, Circulation required round |
S = 260m ², galls 1000 × 6000 × 5mm |
TA2 |
1 |
|
5 |
Two horizontal pipe, Circulation required round |
S = 450m ², Nils 1300 × 6000 × 6mm |
TA2 |
1 |
|
7.5 |
Two horizontal pipe, Circulation required round |
S = 650m ², Nils 1500 × 6000 × 6mm |
TA2 |
1 |
|
10 |
Two horizontal pipe, Circulation required round |
S = 880m ², Nils 1800 × 6000 × 8mm |
TA2 |
1 |
|
Chart of effect chart
Frequently Asked Questions
Q: MVR forced evaporator to run?
Cause: could be the corrosion of secondary steam pipes or steam compressors, pure water quality does not meet the standards, or at the point of equipment such as welding, flange, sealing, expansion, and so on.
Solution: ensure water quality into standards, regularly cleaning the system, maintain stable cooling water temperature, and provide a complete amount of cooling water.
Q: The steam reduction charged by MVR?
Cause: could be due to system clogging or dirt in the hot water catheter.
Solution: do online purification programs for cleaning dirt.
Q: The effect of steam valve charged by MVR?
Cause: The material is processed after thickening, crystally, resulting in clogging.
Solution: The Prevention includes regular filter of salt and spray as well, once stuck, use juice or vacuum treatment.
Q: MVR compulsory evaporator effect?
Expression: Produces regular and loud sound, vibrates the pipes.
Solution: constant current stability compressor when counter rate is soft and open the valve through the appropriate rate; counter rate need to close the compressor immediately for testing, pay attention to liquid temperature to avoid counter rate.
Q: cool MVR evaporator don't work properly?
Cause: could be due to too thick dust, or vacuum drop.
Solution: add agent foaming agent, check detector and dehumidifying liquid, import steam valve adjustment, vacuum control.
S/N | Single effect evaporator | Multi effect evaporator | TVR evaporator | MVR evaporator |
---|---|---|---|---|
Energy source | Using steam heating Steam pipe network Need boiler |
Using steam heating Steam pipe network Need boiler |
Need high pressure steam to drive, Need boiler |
Using electric power, no need steam pipe network close loop circulation system |
Energy consumption | 1 tons steam for 1ton water evaporation | 0.3~1tons steam for 1ton water evaporation | Based on traditional multi effect, one more effect is used with high pressure steam drive | The most energy saving technology at present |
Operation cost | Much higher | More energy saving | Lower | Lowest |
Footprint | smaller | bigger | bigger | smaller |
Product quality | Short residence time, Bigger temp. difference lead to easy scale. product quality not stable |
Longer residence time, Bigger temp. difference lead to easy scale. product quality not stable |
Short residence time, Smaller influence on product quality |
Short residence time, Low temp. evaporation, Minimum impact on product quality |
Control type | Semi-automatic | Full automatic Uninterrupted evaporation |
Full automatic Uninterrupted evaporation |
Full automatic Uninterrupted evaporation |
Previous: Mechanical Vapour Recompression
Next: MVR Evaporator System